<GHG xmlns="http://www.ccdsupport.com/schema/ghg">
<FacilitySiteInformation>
<CertificationStatement>The designated representative or alternate designated representative must sign (i.e., agree to) this certification statement. If you are an agent and you click on  "SUBMIT", you are not agreeing to the certification statement, but are submitting the certification statement on behalf of the designated  representative or alternate designated representative who is agreeing to the certification statement. An agent is only authorized to make the electronic submission on behalf of the designated representative, not to sign (i.e., agree to) the certification statement.</CertificationStatement>
<ReportingYear>2022</ReportingYear>
<FacilitySiteDetails>
<FacilitySite>
<FacilitySiteIdentifier>519991</FacilitySiteIdentifier>
<FacilitySiteName>Subpart W Test Facility</FacilitySiteName>
</FacilitySite>
<LocationAddress>
<LocationAddressText>1710 SAIC Dr</LocationAddressText>
<LocalityName>McLean</LocalityName>
<StateIdentity>
<StateCode>VA</StateCode>
</StateIdentity>
<AddressPostalCode>20010</AddressPostalCode>
</LocationAddress>
<CogenerationUnitEmissionsIndicator>N</CogenerationUnitEmissionsIndicator>
<PrimaryNAICSCode>221210</PrimaryNAICSCode>
<ParentCompanyDetails>
<ParentCompany>
<ParentCompanyLegalName>SAIC</ParentCompanyLegalName>
<StreetAddress>1710 SAIC Dr.</StreetAddress>
<City>Virigina</City>
<State>VA</State>
<Zip>22102</Zip>
<PercentOwnershipInterest>100</PercentOwnershipInterest>
</ParentCompany>
</ParentCompanyDetails>
<TotalNonBiogenicCO2eFacilitySubpartsCtoJJ massUOM="Metric Tons">30635.9</TotalNonBiogenicCO2eFacilitySubpartsCtoJJ>
<TotalBiogenicCO2FacilitySubpartsCtoJJ massUOM="Metric Tons">0</TotalBiogenicCO2FacilitySubpartsCtoJJ>
<TotalCO2eSupplierSubpartsKKtoPP massUOM="Metric Tons">0</TotalCO2eSupplierSubpartsKKtoPP>
<PlantCodeIndicator>N</PlantCodeIndicator>
<SubPartInformation>
<SubPartW>
<GHGasInfoDetails>
<GHGasName>Carbon Dioxide</GHGasName>
<GHGasQuantity massUOM="Metric Tons">
<CalculatedValue>17020.4</CalculatedValue>
</GHGasQuantity>
</GHGasInfoDetails>
<GHGasInfoDetails>
<GHGasName>Methane</GHGasName>
<GHGasQuantity massUOM="Metric Tons">
<CalculatedValue>544.31</CalculatedValue>
</GHGasQuantity>
</GHGasInfoDetails>
<GHGasInfoDetails>
<GHGasName>Nitrous Oxide</GHGasName>
<GHGasQuantity massUOM="Metric Tons">
<CalculatedValue>0.026</CalculatedValue>
</GHGasQuantity>
</GHGasInfoDetails>
<SubPartWReportingFormsDetails>
<SubpartWSummaryDetails>
<SelectedIndustrySegmentNumber>5</SelectedIndustrySegmentNumber>
<SelectedIndustrySegmentName>Underground natural gas storage [98.230(a)(5)]</SelectedIndustrySegmentName>
<Comments>Sample workbook for Underground natural gas storage</Comments>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">17020.4</TotalReportedCarbonDioxideEmissions>
<TotalReportedCarbonDioxideEquivalent massUOM="Metric Tons">30635.9</TotalReportedCarbonDioxideEquivalent>
<TotalReportedCh4Emissions massUOM="Metric Tons">544.31</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.026</TotalReportedN2OEmissions>
<SubpartWSourceReportingFormDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Onshore Production [98.236(aa)(1)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Facility Overview [98.236(aa)(2-11)]</ReportingCategory>
<RequiredForIndustrySegment>Yes</RequiredForIndustrySegment>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Natural Gas Pneumatic Devices [98.236(b)]</ReportingCategory>
<RequiredForIndustrySegment>Yes</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">2.2</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">75.60</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Natural Gas Driven Pneumatic Pumps [98.236(c)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Acid Gas Removal Units [98.236(d)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Dehydrators [98.236(e)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Well Venting for Liquids Unloading [98.236(f)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Completions and Workovers with Hydraulic Fracturing [98.236(g)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Completions and Workovers without Hydraulic Fracturing [98.236(h)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Blowdown Vent Stacks [98.236(i)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Atmospheric Storage Tanks [98.236(j)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Transmission Storage Tanks [98.236(k)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Well Testing [98.236(l)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Associated Gas Venting and Flaring [98.236(m)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Flare Stacks [98.236(n)]</ReportingCategory>
<RequiredForIndustrySegment>Yes</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">16977.3</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">76.69</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.026</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Centrifugal Compressors [98.236(o)]</ReportingCategory>
<RequiredForIndustrySegment>Yes</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">9.1</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">62.76</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Reciprocating Compressors [98.236(p)]</ReportingCategory>
<RequiredForIndustrySegment>Yes</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">28.1</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">195.05</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Equipment Leaks Surveys and Population Counts [98.236(q,r)]</ReportingCategory>
<RequiredForIndustrySegment>Yes</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">3.7</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">134.21</TotalReportedCh4Emissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Offshore Petroleum and Natural Gas Production [98.236(s)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Enhanced Oil Recovery Injection Pumps [98.236(w)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Enhanced Oil Recovery Hydrocarbon Liquids [98.236(x)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
</SubpartWSourceReportingFormRowDetails>
<SubpartWSourceReportingFormRowDetails>
<ReportingCategory>Combustion Equipment at Onshore Petroleum and Natural Gas Production Facilities, Onshore Petroleum and Natural Gas Gathering and Boosting Facilities, and Natural gas Distribution Facilities [98.236(z)]</ReportingCategory>
<RequiredForIndustrySegment>No</RequiredForIndustrySegment>
<TotalReportedCarbonDioxideEmissions massUOM="Metric Tons">0.0</TotalReportedCarbonDioxideEmissions>
<TotalReportedCh4Emissions massUOM="Metric Tons">0.00</TotalReportedCh4Emissions>
<TotalReportedN2OEmissions massUOM="Metric Tons">0.000</TotalReportedN2OEmissions>
</SubpartWSourceReportingFormRowDetails>
</SubpartWSourceReportingFormDetails>
</SubpartWSummaryDetails>
<FacilityOverviewDetails>
<FacilityOverviewUndergroundNaturalGasDetails>
<FacilityOverviewUndergroundNaturalGasRowDetails>
<QuantityOfGasInjected volUOM="thousand standard cubic feet">34463235</QuantityOfGasInjected>
<QuantityOfGasWithdrawn volUOM="thousand standard cubic feet">26696440</QuantityOfGasWithdrawn>
<TotalStorageCapacity volUOM="thousand standard cubic feet">68101064</TotalStorageCapacity>
</FacilityOverviewUndergroundNaturalGasRowDetails>
</FacilityOverviewUndergroundNaturalGasDetails>
</FacilityOverviewDetails>
<PneumaticDeviceVentingDetails>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">2.2</TotalCarbonDioxideEmissions>
<TotalCh4MetricTonsEmissions massUOM="Metric Tons">75.60</TotalCh4MetricTonsEmissions>
<DoesFacilityHaveHighBleedDevices>Yes</DoesFacilityHaveHighBleedDevices>
<DoesFacilityHaveIntermittentBleedDevices>Yes</DoesFacilityHaveIntermittentBleedDevices>
<DoesFacilityHaveLowBleedDevices>Yes</DoesFacilityHaveLowBleedDevices>
<MissingDataProceduresUsed>Yes</MissingDataProceduresUsed>
<PneumaticDeviceTypesDetails>
<PneumaticDeviceTypesRowDetails>
<PneumaticDeviceType>High-bleed Pneumatic Devices</PneumaticDeviceType>
<TotalCount>13</TotalCount>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">1.090196</TotalCarbonDioxideEmissions>
<TotalCh4Emissions massUOM="Metric Tons">37.8045158</TotalCh4Emissions>
<EstimatedNumberOfHours timeUOM="Hours">8760</EstimatedNumberOfHours>
</PneumaticDeviceTypesRowDetails>
<PneumaticDeviceTypesRowDetails>
<PneumaticDeviceType>Intermittent Bleed Pneumatic Devices</PneumaticDeviceType>
<TotalCount>89</TotalCount>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">0.963713</TotalCarbonDioxideEmissions>
<TotalCh4Emissions massUOM="Metric Tons">33.418489</TotalCh4Emissions>
<EstimatedNumberOfHours timeUOM="Hours">8760</EstimatedNumberOfHours>
</PneumaticDeviceTypesRowDetails>
<PneumaticDeviceTypesRowDetails>
<PneumaticDeviceType>Low-Bleed Pneumatic Devices</PneumaticDeviceType>
<TotalCount>20</TotalCount>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">0.1262526</TotalCarbonDioxideEmissions>
<TotalCh4Emissions massUOM="Metric Tons">4.3780378</TotalCh4Emissions>
<EstimatedNumberOfHours timeUOM="Hours">8760</EstimatedNumberOfHours>
</PneumaticDeviceTypesRowDetails>
</PneumaticDeviceTypesDetails>
<PneumaticMissingDataProcTypesDetails>
<PneumaticMissingDataProcTypesRowDetails>
<PdMissingDeviceType>Intermittent Bleed Pneumatic Devices</PdMissingDeviceType>
<PdMissingDataElements>Concentration of CO2 in produced or processed natural gas</PdMissingDataElements>
<PdMissingFrequency>Quarterly</PdMissingFrequency>
<PdMissingQuarters>2</PdMissingQuarters>
<PdMissingProceduresUsed>average of the concentration from quarter before and quarter after</PdMissingProceduresUsed>
</PneumaticMissingDataProcTypesRowDetails>
<PneumaticMissingDataProcTypesRowDetails>
<PdMissingDeviceType>Low-Bleed Pneumatic Devices</PdMissingDeviceType>
<PdMissingDataElements>Concentration of CH4 in produced or processed natural gas</PdMissingDataElements>
<PdMissingFrequency>Monthly</PdMissingFrequency>
<PdMissingHours timeUOM="Hours">2000</PdMissingHours>
<PdMissingProceduresUsed>estimated from subsequent month that monitoring device was working</PdMissingProceduresUsed>
</PneumaticMissingDataProcTypesRowDetails>
</PneumaticMissingDataProcTypesDetails>
</PneumaticDeviceVentingDetails>
<FlareStacksDetails>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">16977.3</TotalCarbonDioxideEmissions>
<TotalCh4MetricTonsEmissions massUOM="Metric Tons">76.69</TotalCh4MetricTonsEmissions>
<TotalN2OMetricTonsEmissions massUOM="Metric Tons">0.026</TotalN2OMetricTonsEmissions>
<DoesFacilityHaveFlareStacks>Yes</DoesFacilityHaveFlareStacks>
<MissingDataProceduresUsed>Yes</MissingDataProceduresUsed>
<UniqueFlareStacksDetails>
<UniqueFlareStacksRowDetails>
<FlareStackIdentifier>Unique Flare Stack ID 1</FlareStackIdentifier>
<WereCemsUsed>Yes</WereCemsUsed>
<Co2Emissions massUOM="Metric Tons">6572</Co2Emissions>
</UniqueFlareStacksRowDetails>
<UniqueFlareStacksRowDetails>
<FlareStackIdentifier>Unique Flare Stack ID 2</FlareStackIdentifier>
<DoesFlareHaveContinuousFlowMonitor>Yes</DoesFlareHaveContinuousFlowMonitor>
<DoesFlareHaveContinuousGasAnalyzer>No</DoesFlareHaveContinuousGasAnalyzer>
<WereCemsUsed>No</WereCemsUsed>
<GasSentToFlare volUOM="Standard Cubic Feet">92743821</GasSentToFlare>
<FlareCombustionEfficiency fractionUOM="fraction (number between 0 and 1)">0.98</FlareCombustionEfficiency>
<FlareFeedGasCH4MoleFraction fractionUOM="decimal fraction">0.95</FlareFeedGasCH4MoleFraction>
<FlareFeedGasCO2MoleFraction fractionUOM="decimal fraction">0.01</FlareFeedGasCO2MoleFraction>
<FractionOfGasSent fractionUOM="decimal fraction">0</FractionOfGasSent>
<Co2Emissions massUOM="Metric Tons">4590.5038105</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">33.8329459</Ch4Emissions>
<N2OEmissions massUOM="Metric Tons">0.0114539</N2OEmissions>
</UniqueFlareStacksRowDetails>
<UniqueFlareStacksRowDetails>
<FlareStackIdentifier>Unique Flare Stack ID 3</FlareStackIdentifier>
<DoesFlareHaveContinuousFlowMonitor>No</DoesFlareHaveContinuousFlowMonitor>
<DoesFlareHaveContinuousGasAnalyzer>No</DoesFlareHaveContinuousGasAnalyzer>
<WereCemsUsed>No</WereCemsUsed>
<GasSentToFlare volUOM="Standard Cubic Feet">117477903</GasSentToFlare>
<FlareCombustionEfficiency fractionUOM="fraction (number between 0 and 1)">0.98</FlareCombustionEfficiency>
<FlareFeedGasCH4MoleFraction fractionUOM="decimal fraction">0.95</FlareFeedGasCH4MoleFraction>
<FlareFeedGasCO2MoleFraction fractionUOM="decimal fraction">0.01</FlareFeedGasCO2MoleFraction>
<FractionOfGasSent fractionUOM="decimal fraction">0</FractionOfGasSent>
<Co2Emissions massUOM="Metric Tons">5814.7567736</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">42.855939</Ch4Emissions>
<N2OEmissions massUOM="Metric Tons">0.0145085</N2OEmissions>
</UniqueFlareStacksRowDetails>
</UniqueFlareStacksDetails>
<UniqueFlarestacksMissingDataProcUsedDetails>
<UniqueFlarestacksMissingDataProcUsedRowDetails>
<UniqueIdentifier>Unique Flare Stack ID 2</UniqueIdentifier>
<MissingDataElements>Mole fraction of CH4 in flare feed gas, XCH4 </MissingDataElements>
<MissingFrequency>Weekly</MissingFrequency>
<MissingHours timeUOM="Hours">336</MissingHours>
<MissingProceduresUsed>Estimated using weekly measurements before and after device malfunction</MissingProceduresUsed>
</UniqueFlarestacksMissingDataProcUsedRowDetails>
<UniqueFlarestacksMissingDataProcUsedRowDetails>
<UniqueIdentifier>Unique Flare Stack ID 3</UniqueIdentifier>
<MissingDataElements>Mole fraction of CO2 in flare feed gas, XCO2</MissingDataElements>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Estimated using the quaterly measurement following</MissingProceduresUsed>
</UniqueFlarestacksMissingDataProcUsedRowDetails>
</UniqueFlarestacksMissingDataProcUsedDetails>
</FlareStacksDetails>
<CentrifugalCompressorsDetails>
<CompressorActivityMissingDataProcUsedDetails>
<CompressorActivityMissingDataProcUsedRowDetails>
<CompressorId>Centrifugal Compressor 2</CompressorId>
<Parameters>Total time in operating mode (hours)</Parameters>
<MissingFrequency>Hourly</MissingFrequency>
<MissingHours timeUOM="Hours">5</MissingHours>
<MissingProceduresUsed>Estimated based on operating mode before and after lcg error</MissingProceduresUsed>
</CompressorActivityMissingDataProcUsedRowDetails>
<CompressorActivityMissingDataProcUsedRowDetails>
<CompressorId>Centrifugal Compressor 2</CompressorId>
<Parameters>Total time in not-operating-depressurized mode (hours) </Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</CompressorActivityMissingDataProcUsedRowDetails>
</CompressorActivityMissingDataProcUsedDetails>
<CompressorLeakOrVentMissingDataProcUsedDetails>
<CompressorLeakOrVentMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
<Parameters>Mole fraction CO2</Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</CompressorLeakOrVentMissingDataProcUsedRowDetails>
<CompressorLeakOrVentMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<Parameters>Measured flow rate (standard cubic feet/hour)</Parameters>
<MissingFrequency>Weekly</MissingFrequency>
<MissingHours timeUOM="Hours">336</MissingHours>
<MissingProceduresUsed>Estimated based on measurements before and after device malfunction</MissingProceduresUsed>
</CompressorLeakOrVentMissingDataProcUsedRowDetails>
</CompressorLeakOrVentMissingDataProcUsedDetails>
<CompressorEmissionFactorsMissingDataProcUsedDetails>
<CompressorEmissionFactorsMissingDataProcUsedRowDetails>
<CompressorMode>Not-operating</CompressorMode>
<CompressorSource>Wet seal</CompressorSource>
<Parameters>Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years</Parameters>
<MissingFrequency>Weekly</MissingFrequency>
<MissingHours timeUOM="Hours">28</MissingHours>
<MissingProceduresUsed>Estimated based on number of measurements taken on days before and after time</MissingProceduresUsed>
</CompressorEmissionFactorsMissingDataProcUsedRowDetails>
<CompressorEmissionFactorsMissingDataProcUsedRowDetails>
<CompressorMode>Not-operating</CompressorMode>
<CompressorSource>Blowdown valve</CompressorSource>
<Parameters>Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years</Parameters>
<MissingFrequency>N/A (i.e., activity data parameters that are determined but not measured)</MissingFrequency>
<MissingProceduresUsed>Estimated by average number of compressors per site</MissingProceduresUsed>
</CompressorEmissionFactorsMissingDataProcUsedRowDetails>
</CompressorEmissionFactorsMissingDataProcUsedDetails>
<CompressorMeasurementMissingDataProcUsedDetails>
<CompressorMeasurementMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
<Parameters>Mole fraction CO2</Parameters>
<MissingFrequency>Daily</MissingFrequency>
<MissingHours timeUOM="Hours">200</MissingHours>
<MissingProceduresUsed>Estimated based on measurements before and after</MissingProceduresUsed>
</CompressorMeasurementMissingDataProcUsedRowDetails>
<CompressorMeasurementMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
<Parameters>Mole fraction CH4</Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>2</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</CompressorMeasurementMissingDataProcUsedRowDetails>
</CompressorMeasurementMissingDataProcUsedDetails>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">9.1</TotalCarbonDioxideEmissions>
<TotalCh4MetricTonsEmissions massUOM="Metric Tons">62.76</TotalCh4MetricTonsEmissions>
<DoesFacilityHaveCentrifugalCompressors>Yes</DoesFacilityHaveCentrifugalCompressors>
<MissingDataProceduresUsed>Yes</MissingDataProceduresUsed>
<CentrifugalCompressorsActivityDataDetails>
<CentrifugalCompressorsActivityDataRowDetails>
<CompressorIdentifier>Centrifugal Compressor 1 </CompressorIdentifier>
<TotalOperatingModeHours timeUOM="Hours">365</TotalOperatingModeHours>
<TotalNotOperatingModeHours timeUOM="Hours">8395</TotalNotOperatingModeHours>
<CompressorMeasuredOperatingMode>No</CompressorMeasuredOperatingMode>
<CompressorMeasuredNotOperatingMode>Yes</CompressorMeasuredNotOperatingMode>
<BlindFlangesInstalled>Yes</BlindFlangesInstalled>
<BlindFlangeInstallationDate>03/20/2018 - 03/25/2018</BlindFlangeInstallationDate>
<SealType>Wet</SealType>
<NumberOfWetSeals>2</NumberOfWetSeals>
<CompressorDriverPowerOutput powerUOM="hp">4250</CompressorDriverPowerOutput>
<HadScheduledShutdown>Yes</HadScheduledShutdown>
</CentrifugalCompressorsActivityDataRowDetails>
<CentrifugalCompressorsActivityDataRowDetails>
<CompressorIdentifier>Centrifugal Compressor 2</CompressorIdentifier>
<TotalOperatingModeHours timeUOM="Hours">827</TotalOperatingModeHours>
<TotalNotOperatingModeHours timeUOM="Hours">7933</TotalNotOperatingModeHours>
<CompressorMeasuredOperatingMode>Yes</CompressorMeasuredOperatingMode>
<CompressorMeasuredNotOperatingMode>Yes</CompressorMeasuredNotOperatingMode>
<BlindFlangesInstalled>No</BlindFlangesInstalled>
<SealType>Dry</SealType>
<CompressorDriverPowerOutput powerUOM="hp">7688</CompressorDriverPowerOutput>
<HadScheduledShutdown>Yes</HadScheduledShutdown>
</CentrifugalCompressorsActivityDataRowDetails>
<CentrifugalCompressorsActivityDataRowDetails>
<CompressorIdentifier>Centrifugal Compressor 3</CompressorIdentifier>
<TotalOperatingModeHours timeUOM="Hours">289</TotalOperatingModeHours>
<TotalNotOperatingModeHours timeUOM="Hours">8471</TotalNotOperatingModeHours>
<CompressorMeasuredOperatingMode>No</CompressorMeasuredOperatingMode>
<CompressorMeasuredNotOperatingMode>Yes</CompressorMeasuredNotOperatingMode>
<BlindFlangesInstalled>No</BlindFlangesInstalled>
<SealType>Dry</SealType>
<CompressorDriverPowerOutput powerUOM="hp">4250</CompressorDriverPowerOutput>
<HadScheduledShutdown>Yes</HadScheduledShutdown>
</CentrifugalCompressorsActivityDataRowDetails>
</CentrifugalCompressorsActivityDataDetails>
<CentrifugalCompressorsCompressorSourceDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 1 </CompressorIdentifier>
<CompressorSource>Blowdown valve</CompressorSource>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
<LeakOrVentIdIfChangesOccurred>Control 1</LeakOrVentIdIfChangesOccurred>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 1 </CompressorIdentifier>
<CompressorSource>Isolation valve</CompressorSource>
<LeakOrVentId>Leak or Vent ID 2</LeakOrVentId>
<LeakOrVentIdIfChangesOccurred>Control 1</LeakOrVentIdIfChangesOccurred>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 1 </CompressorIdentifier>
<CompressorSource>Wet seal</CompressorSource>
<LeakOrVentId>Leak or Vent ID 3</LeakOrVentId>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 2</CompressorIdentifier>
<CompressorSource>Blowdown valve</CompressorSource>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 2</CompressorIdentifier>
<CompressorSource>Isolation valve</CompressorSource>
<LeakOrVentId>Leak or Vent ID 5</LeakOrVentId>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 2</CompressorIdentifier>
<CompressorSource>Wet seal</CompressorSource>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 3</CompressorIdentifier>
<CompressorSource>Blowdown valve</CompressorSource>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 3</CompressorIdentifier>
<CompressorSource>Isolation valve</CompressorSource>
<LeakOrVentId>Leak or Vent ID 7</LeakOrVentId>
</CentrifugalCompressorsCompressorSourceRowDetails>
<CentrifugalCompressorsCompressorSourceRowDetails>
<CompressorIdentifier>Centrifugal Compressor 3</CompressorIdentifier>
<CompressorSource>Wet seal</CompressorSource>
</CentrifugalCompressorsCompressorSourceRowDetails>
</CentrifugalCompressorsCompressorSourceDetails>
<CentrifugalCompressorsLeakOrVentSampleDataDetails>
<CentrifugalCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
<MeasurementDate>2020-05-20</MeasurementDate>
<MeasurementMethod>Screening/Optical gas imaging</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">0</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorOperatingMode>Centrifugal Compressor 1 </CompressorOperatingMode>
</CentrifugalCompressorsLeakOrVentSampleDataRowDetails>
<CentrifugalCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<MeasurementDate>2020-09-01</MeasurementDate>
<MeasurementMethod>Temporary meter</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">3</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorOperatingMode>Centrifugal Compressor 2</CompressorOperatingMode>
</CentrifugalCompressorsLeakOrVentSampleDataRowDetails>
</CentrifugalCompressorsLeakOrVentSampleDataDetails>
<CentrifugalCompressorsEmissionFactorsSampleDataDetails>
<CentrifugalCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Operating</CompressorMode>
<CompressorSource>Wet seal</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">216</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>25</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</CentrifugalCompressorsEmissionFactorsSampleDataRowDetails>
<CentrifugalCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Operating</CompressorMode>
<CompressorSource>Blowdown valve</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">902</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>62</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</CentrifugalCompressorsEmissionFactorsSampleDataRowDetails>
<CentrifugalCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Not-operating</CompressorMode>
<CompressorSource>Isolation valve</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">384</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>8</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</CentrifugalCompressorsEmissionFactorsSampleDataRowDetails>
</CentrifugalCompressorsEmissionFactorsSampleDataDetails>
<CentrifugalCompressorsLeakOrVentMeasurementDetails>
<CentrifugalCompressorsLeakOrVentMeasurementRowDetails>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
<MeasuredVolume volUOM="million standard cubic feet">185226</MeasuredVolume>
<IncludeCompressorBlowdowns>Yes</IncludeCompressorBlowdowns>
<MeasurementLocation>Not manifolded</MeasurementLocation>
</CentrifugalCompressorsLeakOrVentMeasurementRowDetails>
</CentrifugalCompressorsLeakOrVentMeasurementDetails>
<CentrifugalCompressorsLeakOrVentDataDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">0</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">0</Ch4EmissionsVented>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Control 1</LeakOrVentId>
<SingleSourceOrManifoldGroup>Manifold</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Vapor recovery</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">100</PercentageOfTimeDeviceOperational>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 2</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Flare</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">100</PercentageOfTimeDeviceOperational>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 3</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Combustion (fuel or thermal oxidizer)</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">75</PercentageOfTimeDeviceOperational>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">0</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">0.05</Ch4EmissionsVented>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 5</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Flare</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">100</PercentageOfTimeDeviceOperational>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>No</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>Yes</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">0.5</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">3.38</Ch4EmissionsVented>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
<CentrifugalCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 7</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>No</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">8.6</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">59.33</Ch4EmissionsVented>
</CentrifugalCompressorsLeakOrVentDataRowDetails>
</CentrifugalCompressorsLeakOrVentDataDetails>
</CentrifugalCompressorsDetails>
<ReciprocatingCompressorsDetails>
<ReciprocatingCompressorActivityMissingDataProcUsedDetails>
<ReciprocatingCompressorActivityMissingDataProcUsedRowDetails>
<CompressorId>Reciprocating Compressor 3</CompressorId>
<Parameters>Total time in not-operating-depressurized mode (hours) </Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</ReciprocatingCompressorActivityMissingDataProcUsedRowDetails>
<ReciprocatingCompressorActivityMissingDataProcUsedRowDetails>
<CompressorId>Reciprocating Compressor 3</CompressorId>
<Parameters>Total time in standby-pressurized-mode (hours)</Parameters>
<MissingFrequency>Weekly</MissingFrequency>
<MissingHours timeUOM="Hours">200</MissingHours>
<MissingProceduresUsed>Calculated based on activity data from previous weeks</MissingProceduresUsed>
</ReciprocatingCompressorActivityMissingDataProcUsedRowDetails>
</ReciprocatingCompressorActivityMissingDataProcUsedDetails>
<ReciprocatingLeakOrVentMissingDataProcUsedDetails>
<ReciprocatingLeakOrVentMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<Parameters>Mole fraction CO2</Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</ReciprocatingLeakOrVentMissingDataProcUsedRowDetails>
<ReciprocatingLeakOrVentMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<Parameters>Mole fraction CH4</Parameters>
<MissingFrequency>Hourly</MissingFrequency>
<MissingHours timeUOM="Hours">48</MissingHours>
<MissingProceduresUsed>Estimated based on measurements before and after malfunction</MissingProceduresUsed>
</ReciprocatingLeakOrVentMissingDataProcUsedRowDetails>
</ReciprocatingLeakOrVentMissingDataProcUsedDetails>
<ReciprocatingEmissionFactorsMissingDataProcUsedDetails>
<ReciprocatingEmissionFactorsMissingDataProcUsedRowDetails>
<CompressorMode>Standby-pressurized</CompressorMode>
<CompressorSource>Isolation valve</CompressorSource>
<Parameters>Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years</Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</ReciprocatingEmissionFactorsMissingDataProcUsedRowDetails>
<ReciprocatingEmissionFactorsMissingDataProcUsedRowDetails>
<CompressorMode>Not-operating-depressurized</CompressorMode>
<CompressorSource>Blowdown valve</CompressorSource>
<Parameters>Total number of compressors measured in the compressor mode-source combination in current reporting year and preceding two reporting years</Parameters>
<MissingFrequency>Monthly</MissingFrequency>
<MissingHours timeUOM="Hours">300</MissingHours>
<MissingProceduresUsed>Estimated by average number of compressors per site</MissingProceduresUsed>
</ReciprocatingEmissionFactorsMissingDataProcUsedRowDetails>
</ReciprocatingEmissionFactorsMissingDataProcUsedDetails>
<ReciprocatingMeasurementMissingDataProcUsedDetails>
<ReciprocatingMeasurementMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 5</LeakOrVentId>
<Parameters>Mole fraction CO2</Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>Calculated based on activity data from following quarter</MissingProceduresUsed>
</ReciprocatingMeasurementMissingDataProcUsedRowDetails>
<ReciprocatingMeasurementMissingDataProcUsedRowDetails>
<LeakOrVentId>Leak or Vent ID 5</LeakOrVentId>
<Parameters>Mole fraction CH4</Parameters>
<MissingFrequency>Hourly</MissingFrequency>
<MissingHours timeUOM="Hours">65</MissingHours>
<MissingProceduresUsed>Estimated based on measurements before and after </MissingProceduresUsed>
</ReciprocatingMeasurementMissingDataProcUsedRowDetails>
</ReciprocatingMeasurementMissingDataProcUsedDetails>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">28.1</TotalCarbonDioxideEmissions>
<TotalCh4MetricTonsEmissions massUOM="Metric Tons">195.05</TotalCh4MetricTonsEmissions>
<DoesFacilityHaveReciprocatingCompressors>Yes</DoesFacilityHaveReciprocatingCompressors>
<MissingDataProceduresUsed>Yes</MissingDataProceduresUsed>
<ReciprocatingCompressorsActivityDataDetails>
<ReciprocatingCompressorsActivityDataRowDetails>
<UniqueIdentifier>Reciprocating Compressor 1</UniqueIdentifier>
<OperatingModeTotalTime timeUOM="Hours">1983</OperatingModeTotalTime>
<PressurizedModeTotalTime timeUOM="Hours">6390</PressurizedModeTotalTime>
<NotOperatingTotalTime timeUOM="Hours">387</NotOperatingTotalTime>
<CompressorMeasuredOperatingMode>No</CompressorMeasuredOperatingMode>
<CompressorMeasuredPressurizedMode>Yes</CompressorMeasuredPressurizedMode>
<CompressorMeasuredNotOperatingMode>Yes</CompressorMeasuredNotOperatingMode>
<BlindFlangesInstalled>No</BlindFlangesInstalled>
<CompressorDriverPowerOutput powerUOM="hp">3000</CompressorDriverPowerOutput>
<HadScheduledShutdown>No</HadScheduledShutdown>
</ReciprocatingCompressorsActivityDataRowDetails>
<ReciprocatingCompressorsActivityDataRowDetails>
<UniqueIdentifier>Reciprocating Compressor 2</UniqueIdentifier>
<OperatingModeTotalTime timeUOM="Hours">3630</OperatingModeTotalTime>
<PressurizedModeTotalTime timeUOM="Hours">518</PressurizedModeTotalTime>
<NotOperatingTotalTime timeUOM="Hours">4612</NotOperatingTotalTime>
<CompressorMeasuredOperatingMode>Yes</CompressorMeasuredOperatingMode>
<CompressorMeasuredPressurizedMode>No</CompressorMeasuredPressurizedMode>
<CompressorMeasuredNotOperatingMode>No</CompressorMeasuredNotOperatingMode>
<BlindFlangesInstalled>Yes</BlindFlangesInstalled>
<BlindFlangeInstallationDate>01/15/2018 - 01/25/2018</BlindFlangeInstallationDate>
<CompressorDriverPowerOutput powerUOM="hp">5000</CompressorDriverPowerOutput>
<HadScheduledShutdown>Yes</HadScheduledShutdown>
</ReciprocatingCompressorsActivityDataRowDetails>
<ReciprocatingCompressorsActivityDataRowDetails>
<UniqueIdentifier>Reciprocating Compressor 3</UniqueIdentifier>
<OperatingModeTotalTime timeUOM="Hours">8600</OperatingModeTotalTime>
<PressurizedModeTotalTime timeUOM="Hours">100</PressurizedModeTotalTime>
<NotOperatingTotalTime timeUOM="Hours">60</NotOperatingTotalTime>
<CompressorMeasuredOperatingMode>Yes</CompressorMeasuredOperatingMode>
<CompressorMeasuredPressurizedMode>No</CompressorMeasuredPressurizedMode>
<CompressorMeasuredNotOperatingMode>Yes</CompressorMeasuredNotOperatingMode>
<BlindFlangesInstalled>No</BlindFlangesInstalled>
<CompressorDriverPowerOutput powerUOM="hp">1500</CompressorDriverPowerOutput>
<HadScheduledShutdown>Yes</HadScheduledShutdown>
</ReciprocatingCompressorsActivityDataRowDetails>
</ReciprocatingCompressorsActivityDataDetails>
<ReciprocatingCompressorSourceDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 1</UniqueIdentifier>
<CompessorSource>Blowdown valve</CompessorSource>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 1</UniqueIdentifier>
<CompessorSource>Isolation valve</CompessorSource>
<LeakOrVentId>Leak or Vent ID 2</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 1</UniqueIdentifier>
<CompessorSource>Rod packing</CompessorSource>
<LeakOrVentId>Leak or Vent ID 3</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 2</UniqueIdentifier>
<CompessorSource>Blowdown valve</CompessorSource>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<LeakOrVentIdIfChangesOccurred>Control 1</LeakOrVentIdIfChangesOccurred>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 2</UniqueIdentifier>
<CompessorSource>Isolation valve</CompessorSource>
<LeakOrVentId>Leak or Vent ID 5</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 2</UniqueIdentifier>
<CompessorSource>Rod packing</CompessorSource>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 3</UniqueIdentifier>
<CompessorSource>Blowdown valve</CompessorSource>
<LeakOrVentId>Leak or Vent ID 7</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 3</UniqueIdentifier>
<CompessorSource>Isolation valve</CompessorSource>
<LeakOrVentId>Leak or Vent ID 8</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
<ReciprocatingCompressorSourceRowDetails>
<UniqueIdentifier>Reciprocating Compressor 3</UniqueIdentifier>
<CompessorSource>Rod packing</CompessorSource>
<LeakOrVentId>Leak or Vent ID 9</LeakOrVentId>
</ReciprocatingCompressorSourceRowDetails>
</ReciprocatingCompressorSourceDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
<MeasurementDate>2020-01-30</MeasurementDate>
<MeasurementMethod>Acoustic leak detection</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">186</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorStandbyPressurizedMode>Reciprocating Compressor 1</CompressorStandbyPressurizedMode>
</ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 2</LeakOrVentId>
<MeasurementDate>2021-01-30</MeasurementDate>
<MeasurementMethod>Acoustic leak detection</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">0</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorNotOperatingMode>Reciprocating Compressor 1</CompressorNotOperatingMode>
</ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 2</LeakOrVentId>
<MeasurementDate>2020-06-30</MeasurementDate>
<MeasurementMethod>Temporary meter</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">10</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorNotOperatingMode>Reciprocating Compressor 1</CompressorNotOperatingMode>
</ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<MeasurementDate>2020-06-30</MeasurementDate>
<MeasurementMethod>Screening/Optical gas imaging</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">11</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorOperatingMode>Reciprocating Compressor 2</CompressorOperatingMode>
</ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 7</LeakOrVentId>
<MeasurementDate>2020-06-30</MeasurementDate>
<MeasurementMethod>Temporary meter</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">500</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorOperatingMode>Reciprocating Compressor 3</CompressorOperatingMode>
</ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
<LeakOrVentId>Leak or Vent ID 8</LeakOrVentId>
<MeasurementDate>2020-06-30</MeasurementDate>
<MeasurementMethod>Temporary meter</MeasurementMethod>
<MeasurementFlowRate flowUOM="Standard Cubic Feet per Hour">400</MeasurementFlowRate>
<MeasurementLocation>Not manifolded</MeasurementLocation>
<CompressorNotOperatingMode>Reciprocating Compressor 3</CompressorNotOperatingMode>
</ReciprocatingCompressorsLeakOrVentSampleDataRowDetails>
</ReciprocatingCompressorsLeakOrVentSampleDataDetails>
<ReciprocatingCompressorsEmissionFactorsSampleDataDetails>
<ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Operating</CompressorMode>
<CompressorSource>Blowdown valve</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">137</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>112</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Operating</CompressorMode>
<CompressorSource>Rod packing</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">234</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>10</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Standby-pressurized</CompressorMode>
<CompressorSource>Blowdown valve</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">170</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>42</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
<CompressorMode>Not-operating-depressurized</CompressorMode>
<CompressorSource>Isolation valve</CompressorSource>
<CompressorModeEmissionFactor flowUOM="Standard Cubic Feet per Hour">600</CompressorModeEmissionFactor>
<TotalNumberOfCompressors>42</TotalNumberOfCompressors>
<EmissionFactorType>All applicable facilities</EmissionFactorType>
</ReciprocatingCompressorsEmissionFactorsSampleDataRowDetails>
</ReciprocatingCompressorsEmissionFactorsSampleDataDetails>
<ReciprocatingCompressorsLeakOrVentMeasurementDetails>
<ReciprocatingCompressorsLeakOrVentMeasurementRowDetails>
<LeakOrVentId>Leak or Vent ID 9</LeakOrVentId>
<MeasuredVolume volUOM="million standard cubic feet">0.12</MeasuredVolume>
<IncludeCompressorBlowdowns>No</IncludeCompressorBlowdowns>
<MeasurementLocation>Not manifolded</MeasurementLocation>
</ReciprocatingCompressorsLeakOrVentMeasurementRowDetails>
</ReciprocatingCompressorsLeakOrVentMeasurementDetails>
<ReciprocatingCompressorsLeakOrVentDataDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 1</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">3.8</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">26.63</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 2</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">0</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">0.04</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 3</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Combustion (fuel or thermal oxidizer)</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">100</PercentageOfTimeDeviceOperational>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 4</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">0.3</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">2.33</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Control 1</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Flare</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">60</PercentageOfTimeDeviceOperational>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 5</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>No</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">7.3</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">50.47</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 6</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Vapor recovery</LeakOrVentEmissionsReleased>
<PercentageOfTimeDeviceOperational percentUOM="Number (between 0 and 100)">100</PercentageOfTimeDeviceOperational>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 7</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">11.3</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">78.43</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 8</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>Yes</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>No</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">0.1</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">0.44</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
<ReciprocatingCompressorsLeakOrVentDataRowDetails>
<LeakOrVentId>Leak or Vent ID 9</LeakOrVentId>
<SingleSourceOrManifoldGroup>Single</SingleSourceOrManifoldGroup>
<LeakOrVentEmissionsReleased>Atmosphere</LeakOrVentEmissionsReleased>
<AsFoundMeasurementConducted>No</AsFoundMeasurementConducted>
<ContinousMeasurementsConducted>Yes</ContinousMeasurementsConducted>
<Co2EmissionsVented massUOM="Metric Tons">5.3</Co2EmissionsVented>
<Ch4EmissionsVented massUOM="Metric Tons">36.71</Ch4EmissionsVented>
</ReciprocatingCompressorsLeakOrVentDataRowDetails>
</ReciprocatingCompressorsLeakOrVentDataDetails>
</ReciprocatingCompressorsDetails>
<OtherEmissionsFromEquipmentLeaksDetails>
<EmissionsComponentTypeMissingDataProcUsedDetails>
<EmissionsComponentTypeMissingDataProcUsedRowDetails>
<EmissionSourceEquipmentType>Storage Wellheads - Valve</EmissionSourceEquipmentType>
<Parameters>Total number of emission source type, Counte</Parameters>
<MissingFrequency>Semiannually</MissingFrequency>
<MissingHours timeUOM="Hours">48</MissingHours>
<MissingProceduresUsed>averaged measurements from before and after missing measurement</MissingProceduresUsed>
</EmissionsComponentTypeMissingDataProcUsedRowDetails>
<EmissionsComponentTypeMissingDataProcUsedRowDetails>
<EmissionSourceEquipmentType>Storage Wellheads - Connector</EmissionSourceEquipmentType>
<Parameters>Total number of emission source type, Counte</Parameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>estimated using following quarter measurement</MissingProceduresUsed>
</EmissionsComponentTypeMissingDataProcUsedRowDetails>
</EmissionsComponentTypeMissingDataProcUsedDetails>
<ComponentEmissionsFactorsMissingDataProcUsedDetails>
<ComponentEmissionsFactorsMissingDataProcUsedRowDetails>
<MissingCompType>Storage Station, Gas Service - Pressure Relief Valve</MissingCompType>
<MissingEmissionSource>Storage Station, Gas Service - Pressure Relief Valve</MissingEmissionSource>
<MissingServiceType>Storage Station, Gas Service - Pressure Relief Valve</MissingServiceType>
<MissingParameters>Total number of surveyed component type identified as leaking</MissingParameters>
<MissingFrequency>Quarterly</MissingFrequency>
<MissingQuarters>1</MissingQuarters>
<MissingProceduresUsed>estimated using measurement from following quarter</MissingProceduresUsed>
</ComponentEmissionsFactorsMissingDataProcUsedRowDetails>
<ComponentEmissionsFactorsMissingDataProcUsedRowDetails>
<MissingCompType>Storage Station, Gas Service - Meter and Instrument</MissingCompType>
<MissingEmissionSource>Storage Station, Gas Service - Meter and Instrument</MissingEmissionSource>
<MissingServiceType>Storage Station, Gas Service - Meter and Instrument</MissingServiceType>
<MissingParameters>Total number of surveyed component type identified as leaking</MissingParameters>
<MissingFrequency>Semiannually</MissingFrequency>
<MissingHours timeUOM="Hours">72</MissingHours>
<MissingProceduresUsed>averaged measurements from before and after missing measurement</MissingProceduresUsed>
</ComponentEmissionsFactorsMissingDataProcUsedRowDetails>
</ComponentEmissionsFactorsMissingDataProcUsedDetails>
<TotalCarbonDioxideEmissions massUOM="Metric Tons">3.7</TotalCarbonDioxideEmissions>
<TotalCh4MetricTonsEmissions massUOM="Metric Tons">134.21</TotalCh4MetricTonsEmissions>
<EquipmentLeaksViaSurveys>Yes</EquipmentLeaksViaSurveys>
<EquipmentLeaksViaPopulationCounts>Yes</EquipmentLeaksViaPopulationCounts>
<DidFacilityElectToComplyWith98236Q>Yes</DidFacilityElectToComplyWith98236Q>
<MissingDataProceduresUsed>Yes</MissingDataProceduresUsed>
<TotalEquipmentLeaksDuringYear>2</TotalEquipmentLeaksDuringYear>
<OpticalGasImagingInstrument6018>Yes</OpticalGasImagingInstrument6018>
<Method21>Yes</Method21>
<InfraredLaserBeamIlluminatedInstrument>No</InfraredLaserBeamIlluminatedInstrument>
<AcousticLeakDetectionDevice>No</AcousticLeakDetectionDevice>
<OpticalGasImagingInstrument605397A>No</OpticalGasImagingInstrument605397A>
<Method21605397A>No</Method21605397A>
<UndergroundStorageEmissionsFactorsDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Station, Gas Service - Valve</ComponentType>
<TotalLeakingComponentTypes>7</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.4</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">17.03</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Station, Gas Service - Connector (other)</ComponentType>
<TotalLeakingComponentTypes>1</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">0.917</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Station, Gas Service - Open-ended Line</ComponentType>
<TotalLeakingComponentTypes>3</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.1</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">8.49</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Station, Gas Service - Pressure Relief Valve</ComponentType>
<TotalLeakingComponentTypes>1</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.2</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">6.5</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Station, Gas Service - Meter and Instrument</ComponentType>
<TotalLeakingComponentTypes>5</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.4</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">15.85</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Station, Gas Service - Other</ComponentType>
<TotalLeakingComponentTypes>8</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.166248</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">5.3787802</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Wellheads, Gas Service - Valve</ComponentType>
<TotalLeakingComponentTypes>5</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.1140421</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">3.689712</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Wellheads, Gas Service - Connector (other than flanges)</ComponentType>
<TotalLeakingComponentTypes>7</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.0425757</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">1.3774925</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Wellheads, Gas Service - Flange</ComponentType>
<TotalLeakingComponentTypes>1</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.0192604</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">0.6231514</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Wellheads, Gas Service - Open-Ended Line</ComponentType>
<TotalLeakingComponentTypes>5</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.0633567</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">2.04984</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Wellheads, Gas Service - Pressure Relief Valve</ComponentType>
<TotalLeakingComponentTypes>6</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.124686</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">4.0340851</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
<UndergroundStorageEmissionsFactorsRowDetails>
<ComponentType>Storage Wellheads, Gas Service - Other</ComponentType>
<TotalLeakingComponentTypes>7</TotalLeakingComponentTypes>
<AverageTimeComponentsSurveyed timeUOM="Hours">8760</AverageTimeComponentsSurveyed>
<Co2Emissions massUOM="Metric Tons">0.145467</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">4.7064326</Ch4Emissions>
</UndergroundStorageEmissionsFactorsRowDetails>
</UndergroundStorageEmissionsFactorsDetails>
<GasEstimatingEmissionsDetails>
<GasEstimatingEmissionsRowDetails>
<EmissionType>Storage wellheads, Gas Service - Valves</EmissionType>
<SourceTypeCount>2386</SourceTypeCount>
<AverageTimeTypeOperational timeUOM="Hours">8000</AverageTimeTypeOperational>
<Co2Emissions massUOM="Metric Tons">1.1044317</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">35.732736</Ch4Emissions>
</GasEstimatingEmissionsRowDetails>
<GasEstimatingEmissionsRowDetails>
<EmissionType>Storage wellheads, Gas Service - Connector</EmissionType>
<SourceTypeCount>31</SourceTypeCount>
<AverageTimeTypeOperational timeUOM="Hours">8760</AverageTimeTypeOperational>
<Co2Emissions massUOM="Metric Tons">0.0015712</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">0.050836</Ch4Emissions>
</GasEstimatingEmissionsRowDetails>
<GasEstimatingEmissionsRowDetails>
<EmissionType>Storage wellheads, Gas Service - Open-ended line</EmissionType>
<SourceTypeCount>37</SourceTypeCount>
<AverageTimeTypeOperational timeUOM="Hours">8760</AverageTimeTypeOperational>
<Co2Emissions massUOM="Metric Tons">0.0056261</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">0.1820258</Ch4Emissions>
</GasEstimatingEmissionsRowDetails>
<GasEstimatingEmissionsRowDetails>
<EmissionType>Storage wellheads, Gas Service - Pressure Relief Valve</EmissionType>
<SourceTypeCount>990</SourceTypeCount>
<AverageTimeTypeOperational timeUOM="Hours">8760</AverageTimeTypeOperational>
<Co2Emissions massUOM="Metric Tons">0.8530346</Co2Emissions>
<Ch4Emissions massUOM="Metric Tons">27.5990458</Ch4Emissions>
</GasEstimatingEmissionsRowDetails>
</GasEstimatingEmissionsDetails>
</OtherEmissionsFromEquipmentLeaksDetails>
</SubPartWReportingFormsDetails>
</SubPartW>
</SubPartInformation>
</FacilitySiteDetails>
<StartDate>2022-01-01</StartDate>
<EndDate>2022-12-31</EndDate>
<DateTimeReportGenerated>2022-12-13T11:51:38</DateTimeReportGenerated>
</FacilitySiteInformation>
</GHG>